304 Stainless Steel Tube


Technical Data Sheet

 

Chemical Composition Limits
Weight% Cr Ni Mn Si Mo C P S Ti
304 18-20 8-11 2.00 0.75 - 0.080 0.040 0.030 -
304L 18-20 8-13 2.00 0.75 - 0.035 0.040 0.030 -

 

Typical Mechanical Properties

 

Grade Tensile Strength Rm N/mm²
Yield Strength Rp 0.2, N/mm² Elongation (%)
304 Annealed 500-700 195 40
304L Annealed 460-680 180 40

Availability
304 Stainless Steel is available in Capillary tube, Instrument tube, Precision tube and Hydraulic tube. 304 Stainless Steel can also be supplied in Coiled Tube with a seamless and welded execution.

Stainless Steel 304 Capillary tube can be either harddrawn (hardness 260-330 HV) or annealed (hardness <180 HV). The tolerances are according to DIN 17458/ISO 1127 D4/T3. We can also supply Welded/ Redrawn (in the same conditions).  

Capillary tubes can be supplied with various point styles : Blunt end - square cut /Chamfered edge / Radiused/ Tapered. Flat ground-point, Back cut bevel, Lancet level, Closed round end, Flared end and Threaded end.

For all stock availability contact Sales.

Services
At Aircraft Materials we specialise in the rapid turn-around of orders, with most stock items ready for shipping out the same day to anywhere in the world. For time-critical orders, such as AOGs use our AOG service desk (aog@aircraftmaterials.com), the team are dedicated to processing and dispatching orders on the same day, even for cutting orders on bar and sheet products.

Our expertise in global logistics enables us to source material from anywhere in the world in a matter of days and provide fast shipping solutions to all our customers, whichever country they are in. We use a range of transport partners to ship overnight within the UK and Europe, and offer a full range of logistics solutions from priority express services to more cost-effective economy shipments all around the globe. To find out more about our services click here.

Disclaimer